| Modelo | .Rechargeablebattery_US | .Opt5 | .Opt4 | .Opt2 | .Opt3 | .Opt6 | .Opt8 | .Opt1 | .Opt9 | .Opt7 | | |
| Parámetro | pH/mV."C | √ | - | - | - | - | √ | √ | - | √ | √ | |
| mV(ORP)."C | √ | √ | - | - | - | √ | √ | - | √ | √ | | |
| Cond/TDS/Sal/Res."C | - | - | √ | - | - | √ | - | √ | - | √ | | |
| DO"C | - | - | - | √ | √ | - | √ | √ | - | √ | | |
| pH | Rango de medición | (-2.000-20.000)pH | - | - | - | - | - | √ | √ | - | √ | √ |
| Resolución | 0.1/0.01/0.001 | - | - | - | - | - | √ | √ | - | √ | √ | |
| Precisión | ±0.002pH + one digit | - | - | - | - | - | √ | √ | - | √ | √ | |
| Puntos de calibración | 1-3 pts auto | - | - | - | - | - | √ | √ | - | √ | √ | |
| Rango ATC | 0-100℃(32-212“F) | - | - | - | - | - | √ | √ | - | √ | √ | |
| ORP | Rango de medición | (-1999.9 -+1999.9)mV | √ | - | - | - | - | √ | √ | - | √ | √ |
| Resolución | 0.1/1 | √ | - | - | - | - | √ | √ | - | √ | √ | |
| Precisión | ±0.03%F.S ± one digit | √ | - | - | - | - | √ | √ | - | √ | √ | |
| Conductividad | Rango de medición | 0-2000.0mS/cm Auto divided by range Match test range: 0-200mS/cm TDS:0 - 100.0g/L(Factor adjustable) Resistivity:5.000Ω·cm-100.0MΩ·cm Salinity:(0.00.100.00)ppt | - | - | √ | - | - | √ | - | √ | - | √ |
| Puntos de calibración | One point | - | - | √ | - | - | √ | - | √ | - | √ | |
| Resolución | 0.001 | - | - | √ | - | - | √ | - | √ | - | √ | |
| Rango ATC | (0.0-50.0)℃/(32.0-122.0)℉ | - | - | √ | - | - | √ | - | √ | - | √ | |
| Precisión | ±0.5% F.S ± one digit | - | - | √ | - | - | √ | - | √ | - | √ | |
| DO | Rango de medición | 1000-20.00mg/L | - | - | - | √ | √ | - | √ | √ | - | √ |
| Precisión | ±0.30 mg/L | - | - | - | √ | ±0.20mg/L | - | √ | √ | - | √ | |
| Saturación de DO | (0.0-200.0)% | - | - | - | √ | √ | - | √ | √ | - | √ | |
| Compensación de presión barométrica | (0-200 0) kPa Automático | - | - | - | √ | √ | - | √ | √ | - | √ | |
| Compensación de temperatura | (0.0 - 50.0)℃/(32.0 - 122.0)℉ Automático | - | - | - | √ | √ | - | √ | √ | - | √ | |
| Compensación de Salinidad | 0-45ppt Manual | - | - | - | √ | √ | - | √ | √ | - | √ | |
| Temperatura | Rango de medición | (-10.0-135.0P'C/14.0-275. 0)F | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ |
| Precisión | ±0.2℃ | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | |
| Otros | Data export/Charging socket | Type-C | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ |
| Fuente de alimentación | Rechargeable battery/USB | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | |
| Clasificación IP | IP57 | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | |
| Kit de prueba | Meter | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | |
| Sonda de pH ATC de plástico 201T-H | √ | - | - | - | - | √ | √ | - | √ | √ | | |
| Sonda ORP de plástico ORP301 | - | √ | - | - | - | - | - | - | √ | - | | |
| Sonda de temperatura de acero inoxidable TEMP-02H | - | √ | - | - | - | - | - | - | √ | - | | |
| Sonda de conductividad ATC de plástico CON201T. K=1.0 | - | - | √ | - | - | √ | - | √ | - | √ | | |
| Sonda de DO polarográfica DO01-2M-H,longitud del cable:2m | - | - | - | √ | - | - | √ | √ | - | √ | | |
| Sonda DO óptica ODO01-3M, longitud del cable: 3m | - | - | - | - | √ | - | - | - | - | - | | |
| Solución tampón de pH: pH4 00/7,00/10.01, 50mL, uno para cada uno | √ | - | - | - | - | √ | √ | - | √ | √ | | |
| Solución estándar de ORP: 222mV, 50mL,1btl | - | √ | - | - | - | - | - | - | √ | - | | |
| Solución estándar de conductividad 84μS/1413μS/12.88mS/cm 50mL, una para cada | - | - | √ | - | - | √ | - | √ | - | √ | | |
| Solución de recarga de membrana DO DOS-01, 30mL, 1bt | - | - | - | √ | - | - | √ | √ | - | √ | | |
| Tapas de sensor de membrana DO DOSC: 3 unidades/grupo, 1 paquete | - | - | - | √ | - | - | √ | √ | - | √ | | |
| Batería de litio recargable (preinstalada) | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | | |
| Exportación de datos/Cable de carga: 1oc | √ | √ | √ | √ | √ | √ | √ | √ | √ | √ | | |
| Estuche rígido de transporte (L/An/Al:33.0×27.2×8.2cm) | √ | √ | √ | √ | √ | - | - | - | - | - | | |
| Estuche rígido de transporte (L/An/Al; 36.0×32. 0×9.0cm) | - | - | - | - | - | √ | √ | √ | √ | √ | | |