Introducing the Asphalt Mixture Automated Testing System with Zero Intervention, developed by Dr. Fujie Zhou at Texas A&M University and manufactured by Humboldt. This cutting-edge system automates Balanced Mix Design (BMD), enhancing the accuracy and efficiency of asphalt mixture testing. The Asphalt Mixture Automated Testing System significantly advances asphalt mixturetesting.
This innovative system meets the current demands for BMD testing and addresses the industry's challenges, including labor shortages and human error. Experience a new standard in asphalt mixture testing that prioritizes efficiency andconsistency.
How it Works:
Automated Testing: Our system automates the entire testing process, from specimen preparation to dataanalysis.
Precision and Accuracy: Benefit from highly accurate and consistent results, thanks to our advancedtechnology.
Efficiency and Speed: Achieve faster turnaround times and increasedproductivity.
Key Features:
Fully Automated: Eliminate human error and reduce laborcosts.
Comprehensive Testing: Perform a wide range of essential tests. (see full listbelow)
Balanced Mix Design (BMD): Ensure optimal asphalt performance through advanced testingmethodologies.
Industry-Leading Standards: Adhere to ASTM, AASHTO, and local testingprocedures.
Benefits:
Quality Control/Quality Acceptance (QC/QA): Seamlessly integrate testing into daily operations during mix production, ensuring the quality and consistency of asphaltmixtures.
Identify and Eliminate: Quickly identify cracking- or rutting-prone mixes before they are placed on roads, enhancing roadway durability andsafety.
Comprehensive Testing Methods
Enhanced Efficiency: Streamline your testing process and reduce turnaroundtime.
Improved Accuracy: Minimize human error and ensure consistent, reliableresults.
Cost Savings: Reduce labor costs and increaseproductivity.
Data-Driven Decisions: Make informed decisions based on accurate and comprehensive testdata.
3 Year StandardWarranty
The system supports various ASTM test methods,including:
ASTM D3549 - Measuring sample height anddiameter
ASTM D2726 - Bulk specific gravity, density, and air voidcalculation
ASTM D6927 - Marshall testmethod
ASTM D6931 - Indirect tensiletest
ASTM D8225 - IDEAL-CT testmethod
ASTM D8360 - IDEAL-RT testmethod
Advantages of Automation:
Improved Accuracy/Consistency: Removes humanerrors
Zero intervention intesting.
Enhanced safety foroperators
Increased productivity and efficiency resulting in higheroutput.
Enhanced quality control
Reduced labor costs
System Components:
Robot Arm and DockingStation
Specimen Identification
Specimen Feeding Carousel
Air Voids MeasurementUnit
Specimen storage unit
Two conditioning chambers
Specimen rapid dryunit
Loading frame with trashingunit
Power supplying
Please Note: Individual components can be sold separately to workindependently.