With built-in Ambient RH + Temperature sensor; Plug-in Contact Temp Probe (optional) providing the best available accuracy tolerances; optional plug-in Relative Humidity Probes or Hygro-i2 RH probes for measuring Equilibrium Relative Humidity, Temperature, Dew Point and Humidity Ratio in structural materials. A structural material such as a concrete slab can be tested using the in-situ method or RH Hood methods (International Standards: ASTM F2170 & BS 8201, 8203, 5325).
| Size: |
3.94” x 3.54” x 1.38” (100mm x 90mm x35mm) |
| Weight: |
3.53oz (100g) |
| Construction: |
ABS enclosure |
| Power: |
1 x AA type battery 1.5 Volt |
| Memory: |
100,000 data point entries (samples of Ambient RH and temperature; Surface Temperature) |
| Logging Rate: |
Logger interval adjustable between 10 minutes and 1 hour |
| Transmission Range: |
Up to 165ft (50m) line-of-sight |
| Bluetooth: |
BLE Bluetooth Low Energy 4.2 compliant |
| Included: |
Wall Mounting and Tripod Stand |
Supported measurements:
- Ambient Relative Humidity, Temperature, Dew point, Grains per pound.
- Psychrometric chart showing Relative Humidity, Specific Volume, Wet Bulb Temperature, Dry Bulb Temperature, Enthalpy, Humidity Ratio, Dew Point.
- Contact Temperature, Estimated contact RH, Ambient Dew Point, Contact Delta Temperature (with optional Contact Temperature Probe)
Humidity specifications:
| Range: |
0 to 100%RH |
| Accuracy: |
±1.5%RH Range 0% to 80%RH ±2.0%RH Range 80% to 99%RH (@ 77ºF (25ºC)) |
| Resolution: |
0.1% over the complete range |
| Drift: |
<0.25%RH per year |
Temperature specifications:
| Range: |
-4ºF to 158ºF( -20°C to 70°C) |
| Accuracy: |
±0.1ºF Range -4ºF to 158ºF(±0.1 °C Range -20°C to 70°C) |
| Sensor Protection: |
PTFE Film protects sensor opening from water & dust Drift: <0.04ºF (0.03ºC) per year |
Contact temperature probe (optional):
| Units: |
ºF (ºC) |
| Temperature Range: |
-20°F to +175°F (-30°C to +80°C) |
| Accuracy: |
±0.9ºF from 14ºF to 185ºF (±0.5°C from -10°C to +85°C) |
| Resolution: |
0.1% over the complete range |
Battery:
| Power supply: |
1 x AA type battery 1.5 Volt |
| Battery life: |
Over 1 year based on logging intervals of 5mins, using an alkaline battery with a nominal voltage of 1.5V as supplied. |