The Flooring Installer Kit FINSK is a compact kit for instant and precise moisture testing of concrete (URL: https://tramexmeters.com/moisture-testing/concrete) and wood flooring (URL: https://tramexmeters.com/moisture-testing/flooring) .
The Tramex CMEX5 digital moisture meter allows for non-destructive quantitative testing of concrete (URL: https://tramexmeters.com/moisture-testing/concrete/non-destructive-concrete-moisture-test) and comparative testing per ASTM F2659.
The Tramex heavy-duty wood pin-probe measures the moisture content of wood.
An infrared surface thermometer gives surface temperature and dew point conditions used in conjunction with the CMEX5 hygrometer.
The Flooring Installer Kit comes with an extension handle in a protective Tramex easy-travel case.
The Tramex Meters App allows you to GeoTag test results (URL: https://tramexmeters.com/learn/geotag-feature-in-the-tramex-meters-app-and-the-5-series-meters) , create, save and share reports and charts, as well as see your meter screen on your phone when extending to hard to reach places.
Concrete Moisture Encounter CMEX5 - Measuring Range:
Depth of penetration in concrete: | approx. ¾" (20mm)
Moisture content for Concrete: | 0 → 6.9 %
Comparative for Gypsum floor screed: | 0 → 12
CM Equiv Anhydrite/Concrete: | 0→2.7 / 0→4.3
Reference scale: | 0 → 100
Relative Humidity: | 0 → 99%
(with optional Hygro-i2 ® probe): | Humidity accuracy: 0% → 99%RH +/- 2% @ 25°C / 77°F
Moisture content for wood (with optional wood pin probes): | 5 → 30 %
Infrared Thermometer IRT2
Temperature range: | -58ºF ~ 1202ºF (-50 to 650 ºC)
Distance to Spot ratio: | D:S = 12:1
Display resolution: | 0.1 ºF(0.1ºC) <1000 1ºC >1000
Accuracy for targets: | Assumes ambient operating temperature of 73 to 77ºF (23 to 25 ºC) -58ºF ~ 68ºF (-50 ~ 20ºC)±4.5ºF (2.5ºC) 68ºF ~572ºF (20ºC ~300ºC) ±1.0% ± 1.8ºF (1.0ºC) 572ºF ~ 1202ºF (300ºC ~650ºC) ±1.5%
Repeatability: | -58~68ºF (-50~20ºC) : ± 2.3ºF (1.3ºC) 68~1202ºF (20~650ºC) : ±0.5% or ±0.9ºF (0.5ºC)
Response time: | 150ms
Spectral response: | 8~14um
Emissivity: | Digitally adjustable from 0.10 to 1.0
Over range indication: | LCD will show “----”
Polarity: | Automatic (no indication for positive polarity); Minus (-) sign for negative polarity
Diode laser output: | <1mW,Wavelength 630~670nm, Class 2 laser product
Operating temp.: | 32 to 122ºF ( 0 to 50ºC)
Storage temp.: | 14 to 140ºF (–10 to 60ºC)
Relative humidity: | 10%~90%RH operating, <80%RH storage
Power supply: | 9V battery, NEDA 1604A or IEC 6LR61, or equivalent
Safety: | “ CE ” Comply with EMC
Specifications of Kit:
Size: | 14.5” x 11” x 3.5” (37cm x 28cm 9cm)
Weight: | 3.4lbs (1.55kg)
Power: | 2 x AA batteries, 1 x 9 volt PP3 battery