The Tramex Flooring Master Kit X is the topmost kit including the top of the range digital meters for instant, non-destructive quantitative moisture content testing of concrete and wood flooring, as well as measuring and monitoring of RH and dew point testing of concrete and ambient conditions, both pre- & post-application of floor covering materials.
Featuring the Tramex CMEX5 (URL: https://tramexmeters.com/moisture-meters/cmex5-concrete-moisture-encounter) digital concrete moisture meter for non-destructive quantitative moisture testing of concrete using Gravimetric testing as a baseline, comparative testing per ASTM F2659, and ambient conditions.
The CMEX5 incorporates bayonet plug-in heavy-duty pin-probes measuring moisture content in wood or WME in other flooring materials.
The CMEX5 also incorporates reusable Tramex Hygro-i2 RH probes (URL: https://tramexmeters.com/hygro-i2-probes/hygro-i2-probe) for in-situ testing of concrete as per ASTM F2170 (URL: https://tramexmeters.com/moisture-testing/concrete/in-situ-concrete-rh-test-ASTM-F2170) . Tramex Hygro-i2 RH probes can be used with the Tramex Feedback Datalogger (URL: https://tramexmeters.com/sensors/dl-rhtx-feedback-datalogger) to give live readings and time logs of relative humidity, temperature and dew point in situ and in the environment.
The Tramex MEX5 (URL: https://tramexmeters.com/mex5-moisture-encounter) allows for moisture testing of wood, includes a shallow-depth allows for measurement up to ⅜’ (9mm) and the elimination of substrate influence on readings when needed, and allows for SG specific gravity adjustment, wood species selection and a built-in infrared surface thermometer and pin temperature correction for wood moisture content precision.
The Tramex Flooring Master Kit X comes with an extension handle in a heavy-duty Tramex travel case. Bluetooth connectivity to the Tramex Meters App (URL: https://tramexmeters.com/tramex-meters-app) allows for visualization of readings and data reporting to mobile devices, to GeoTag test results (URL: https://tramexmeters.com/learn/geotag-feature-in-the-tramex-meters-app-and-the-5-series-meters) , create, save and share photos, reports and charts, as well as see your meter screen on your phone when extending to hard to reach places.
Concrete Moisture EncounterCMEX5 - Measuring Range:
Depth of penetration in concrete: | approx. 20mm (¾")
Moisture content for Concrete: | 0 → 6.9 %
Comparative for Gypsum floor screed: | 0 → 12
CM Equiv Anhydrite/Concrete: | 0→2.7 / 0→4.3
Reference scale: | 0 → 100
Relative Humidity: | 0 → 99%
(with optional Hygro-i2 ® probe): | 0% → 99%RH +/- 2% @ 25°C / 77°F
Moisture content for wood (with optional wood pin probes): | 5 → 30 %
Moisture Encounter MEX5 -Measuring Range:
NDT Moisture content for Wood: | 0 → 30% MC
NDT Comparative for Building Materials: | 0 → 100
Pin % MC Wood: | 6 → approx 50% MC
Pin % MC Drywall: | 0 → 8.5% MC
Relative Humidity: | 0 → 99%
(with optional Hygro-i2 ® probe): | Humidity accuracy: 0% → 99%RH +/- 2% @ 25°C / 77°F
Feedback Datalogger DL-RHTX Measuring Range:
Memory: | 100,000 data point entries (samples of Ambient RH and temperature; SurfaceTemperature)
Logging Rate: | Logger interval adjustable between 10 minutes and 1 hour
Transmission Range: | Up to 50m (165ft) line-of-sight
Bluetooth: | BLE Bluetooth Low Energy 4.2 compliant
Relative Humidity Sensor specifications:
Range: | 0 to 100%RH
Accuracy: | ±1.5%RH Range 0% to 80%RH ±2.0%RH Range 80% to 99%RH (@ 25ºC (77ºF))
Resolution: | 0.1% over the complete range
Drift: | <0.25%RH per year
Temperature Sensor specifications:
Range: | -4ºF to 158ºF( -20°C to 70°C)
Accuracy: | ±0.1ºF Range -4ºF to 158ºF(±0.1 °C Range -20°C to 70°C)
Sensor Protection: | PTFE Film protects sensor opening from water & dust Drift: <0.04ºF (0.03ºC) per year
Drift: | <0.04ºF (0.03ºC) per year
Infrared Thermometer IRT2
Temperature range: | -58ºF ~ 1202ºF (-50 to 650 ºC)
Distance to Spot ratio: | D:S = 12:1
Display resolution: | 0.1 ºF(0.1ºC) <1000 1ºC >1000
Accuracy for targets: | Assumes ambient operating temperature of 73 to 77ºF (23 to 25 ºC) -58ºF ~ 68ºF (-50 ~ 20ºC)±4.5ºF (2.5ºC) 68ºF ~572ºF (20ºC ~300ºC) ±1.0% ± 1.8ºF (1.0ºC) 572ºF ~ 1202ºF (300ºC ~650ºC) ±1.5%
Repeatability: | -58~68ºF (-50~20ºC) : ± 2.3ºF (1.3ºC) 68~1202ºF (20~650ºC) : ±0.5% or ±0.9ºF (0.5ºC)
Response time: | 150ms
Spectral response: | 8~14um
Emissivity: | Digitally adjustable from 0.10 to 1.0
Over range indication: | LCD will show “----”
Polarity: | Automatic (no indication for positive polarity); Minus (-) sign for negative polarity
Diode laser output: | <1mW,Wavelength 630~670nm, Class 2 laser product
Operating temp.: | 32 to 122ºF ( 0 to 50ºC)
Storage temp.: | 14 to 140ºF (–10 to 60ºC)
Relative humidity: | 10%~90%RH operating, <80%RH storage
Power supply: | 9V battery, NEDA 1604A or IEC 6LR61, or equivalent
Safety: | “ CE ” Comply with EMC
Specifications of Kit:
Size: | 20.5” x 18.9” x 5.9” (52cm x 48cm x 15cm)
Weight: | 13.2 lbs (6kg)
Power: | 5 x AA batteries, 1 x 9 volt PP3 battery