Glass Fiber Filters

GradeFeatures & ApplicationsNominal RetentionThicknessWeight (g/m²)Water Flow aMax. Op. Temp.BinderWhatman Equivalent
Sterlitech™
934 AHStandard for suspended solids content and related measurements (SM 2540D and EPA Methods 160.2).1.5 µm0.43 mm6447550°CNone934-AH
Grade APrecipitate proteins and cell filtration, scintilliation counting, determination of airborne particulate.1.6 µm0.3 mm5512475°CNoneGF/A
Grade A-ESuspended solids and air monitoring. HEPA type air filter.1 µm0.33 mm6015475°CNone-
Grade BCollection of denatured biochemical polymers. Gas filter or prefilter.1 µm0.65 mm14030475°CNoneGF/B
Grade CRIA procedures and harvesting lymphocytes.1.2 µm0.28 mm5025475°CNoneGF/C
Grade DHigher volume and repetitive laboratory filtering. General prefilter.2.7 µm0.6 mm1205475°CNoneGF/D
Grade ESuspended particle analysis in water, cell harvesting, prefiltration and air monitoring applications.1.5 µm0.35 mm7012475°CNone-
Grade FDiluted aqaueous solutions containing strong oxidizing, acidic, or alkaline components prior to laser spectroscopy. Meets requirements for EPA Method 1311 (TCLP).0.7 µm0.4 mm8080475°CNoneGF/F
TCLPAcid treated and multi-stage deionized water rinsed. Meets requirements for US EPA Method 1311.0.7 µm0.4 mm8080475°CNoneGF/F
Grade TSSDesigned for EPA Methods 2540C and 2540D for testing dissolved and suspended solids in water and wastewater. Excellent wet strength. HEPA type air filter.1.5 µm0.43 mm6447475°CNone-
Grade VSSMeets requirements for Standard Method 2540E, 2540C, 2540D, and EPA Method 160.2. Air pollution monitoring, high temperature flue gas and filtration of high temperature solvents.1.5 µm0.43 mm6447550°CNone-
Advantec™
DP-70High wet strength, very high loading capacity. Dust measurement.0.6 µm0.52 mm17020120°COrganic-
GA-55General purpose paper, air pollution monitoring. HEPA type air filter.0.6 µm0.21 mm5523500°CNoneGF/A
GA-100General purpose paper. Filter precipitated proteins or cells. Air pollution monitoring.1 µm0.44 mm11011500°CNone-
GA-200Thick filter. Viscous fluid filtration (sugars and gels). HEPA type air filter.0.8 µm0.74 mm17515500°CNone-
GB-100RLow trace metal content of As, Pb, and Cd. High and low volume aerosol testing for airborne dust and metal contaminants. DNA/RNA and protein precipitate filtration. HEPA type air filter.0.6 µm0.4 mm9515500°CNoneEPM2000
GB-140Compared to GB-100R: Thicker, greater wet strength, slower filtration speed. Industrial waste analysis. HEPA type air filter.0.4 µm0.56 mm14058500°CNoneGF/B
GC-50Common prefilter (for 0.45 µmm or smaller pore sizes). Scintillation counting. Suspended solids analysis of industrial water and wastewater. HEPA type air filter.0.5 µm0.19 mm4828500°CNoneGF/C, 934-AH
GC-90High wet strength. Filter for clinical screening. HEPA type air filter.0.5 µm0.3 mm10020120°COrganic-
GD-120High wet strength, very high loading capacity. Common prefilter (for 1.2 µm or smaller pore sizes).0.9 µm0.51 mm12314500°CNoneGF/D
GF-75Most retentive grade. Suitable for collection of IgC and other very fine protein precipitates. Clarifies chemically aggressive solutions. Meets requirements for TCLP (EPA method 1311). HEPA type air filter.0.3 µm0.35 mm7584500°CNoneGF/F
GS-25Limited dirt holding capacity, high wet strength. Common prefilter (for 0.65 µm or smaller pore sizes). HEPA type air filter.0.6 µm0.22 mm7015120°COrganic-
QR100 (Quartz)Superior chemical resistance. Acidic gas sampling at high (>500°C) temperatures, pollution analysis. Pre-fired at 1000°C for 2 hours to reduce organic contamination. HEPA type air filter.-0.38 mm85-1000°CNoneQM-A
QR200 (Quartz)Superior chemical resistance, does not absorb acidic gases. Sample acidic gases at high (>500°C) temperatures, pollution analysis.HEPA type air filter.-1 mm200-1000°CInorganic-